Dual-Plate Gold-Gold Microtrench Electrodes for Generator-Collector Voltammetry without Supporting Electrolyte

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/80807
Información del item - Informació de l'item - Item information
Título: Dual-Plate Gold-Gold Microtrench Electrodes for Generator-Collector Voltammetry without Supporting Electrolyte
Autor/es: Montiel, Miguel A. | Iniesta, Jesus | Gross, Andrew J. | Marken, Frank
Grupo/s de investigación o GITE: Electroquímica Aplicada y Electrocatálisis
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Química Física | Universidad de Alicante. Instituto Universitario de Electroquímica
Palabras clave: Ionic strength | Diffusion | Feedback | Sensing | Voltammetry
Área/s de conocimiento: Química Física
Fecha de publicación: 10-ene-2017
Editor: Elsevier
Cita bibliográfica: Electrochimica Acta. 2017, 224: 487-495. doi:10.1016/j.electacta.2016.11.103
Resumen: A gold-gold dual-plate microtrench electrode system based on two oppositely placed gold surfaces with 5 mm length, 17 μm average depth, and 6 μm inter-electrode gap is employed in generator-collector configuration in a four-electrode cell (counter electrode, reference electrode, and two independent working electrodes denoted “generator” – with scanning potential – and “collector” – with fixed potential). The dual-plate microtrench electrodes were investigated for (i) the reduction of Ru(NH3)63+, (ii) the oxidation of ferrocenemethanol, and (iii) the oxidation of iodide in aqueous media, all as a function of supporting electrolyte concentration. It is shown that due to the inter-electrode feedback character of the generator-collector currents, well-defined steady state sensor responses are obtained for the collector electrode even in the absence of added electrolyte. The variation in the mass transport limited steady state current (measured at the collector electrode) with addition/removal of supporting electrolyte remains low (compared to unexpectedly stronger effects caused by the switch between reduction and oxidation conditions at the collector electrode). Microtrench electrode systems are suggested for sensing applications without/with varying levels of supporting electrolyte.
Patrocinador/es: A.J.G and F.M gratefully acknowledge the Engineering and Physical Sciences Research Council (EP/I028706/1) for financial support. M.A.M and J.I. thank the MICINN-FEDER for financial support (CTQ2013-48280-C3-3-R).
URI: http://hdl.handle.net/10045/80807
ISSN: 0013-4686 (Print) | 1873-3859 (Online)
DOI: 10.1016/j.electacta.2016.11.103
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2016 Elsevier Ltd.
Revisión científica: si
Versión del editor: https://doi.org/10.1016/j.electacta.2016.11.103
Aparece en las colecciones:INV - LEQA - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2017_Montiel_etal_ElectActa_final.pdfVersión final (acceso restringido)3,85 MBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.