Inter-rater reliability of trained and untrained raters for measuring jump height with the MyJump app

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/77068
Registre complet
Registre complet
Camp Dublin Core Valor Idioma
dc.contributorResearch in Physical Education, Fitness and Performance (RIPEFAP)es_ES
dc.contributor.authorPueo, Basilio-
dc.contributor.authorJimenez-Olmedo, Jose Manuel-
dc.contributor.authorPenichet-Tomás, Alfonso-
dc.contributor.authorBernal-Soriano, Mari Carmen-
dc.contributor.otherUniversidad de Alicante. Departamento de Didáctica General y Didácticas Específicases_ES
dc.date.accessioned2018-07-04T07:33:03Z-
dc.date.available2018-07-04T07:33:03Z-
dc.date.issued2018-06-30-
dc.identifier.citationJournal of Physical Education and Sport (JPES). 2018, 18(2), Art 121: 821-824. doi:10.7752/jpes.2018.02121es_ES
dc.identifier.issn2247-8051 (Print)-
dc.identifier.issn2247-806X (Online)-
dc.identifier.urihttp://hdl.handle.net/10045/77068-
dc.description.abstractSmartphone apps have been very popular among researchers, coaches and clinicians. The aim of this study was to analyze the inter-rater reliability of trained and untrained raters of the iOs app MyJump. Eighteen participants completed eight counter-movement jumps (CMJ) each (n=144) which were recorded using the app. In order to examine inter-rater reliability derived from raters’ experience, independent assessments were obtained by an untrained rater and two trained raters of the same recordings. Results showed very high agreement between trained raters (ICC=0.982, α=0.991) and between trained and untrained raters (ICC=0.984, α=0.992). Bland-Altman plots depicted negligible bias between both types of raters. Finally, very good internal consistency was found, regardless of experience (α from 0.995 to 0.997 and CV from 1.1 to 1.4%). This study have shown no significant difference in performance of trained and untrained raters of MyJump, and therefore no special training must be observed for an accurate use of the app.es_ES
dc.languageenges_ES
dc.publisherUniversity of Piteşti, Romaniaes_ES
dc.rightsThis work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0es_ES
dc.subjectInstrumentationes_ES
dc.subjectAgreementes_ES
dc.subjectConsistencyes_ES
dc.subjectSmartphonees_ES
dc.subjectMeasurees_ES
dc.subjectObservationes_ES
dc.subject.otherEducación Física y Deportivaes_ES
dc.titleInter-rater reliability of trained and untrained raters for measuring jump height with the MyJump appes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.peerreviewedsies_ES
dc.identifier.doi10.7752/jpes.2018.02121-
dc.relation.publisherversionhttps://doi.org/10.7752/jpes.2018.02121es_ES
dc.identifier.cvIDA9355416-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
Apareix a la col·lecció: INV - SCAPE - Artículos de Revistas
INV - HEALTH-TECH - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
Thumbnail2018_Pueo_etal_JPES.pdf236,69 kBAdobe PDFObrir Vista prèvia


Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.