LCoS display phase self-calibration method based on diffractive lens schemes
Empreu sempre aquest identificador per citar o enllaçar aquest ítem
http://hdl.handle.net/10045/76367
Títol: | LCoS display phase self-calibration method based on diffractive lens schemes |
---|---|
Autors: | Zhang, Haolin | Lizana Tutusaus, Ángel | Iemmi, Claudio | Monroy-Ramírez, Freddy A. | Márquez, Andrés | Moreno Soriano, Ignacio | Campos Coloma, Juan |
Grups d'investigació o GITE: | Holografía y Procesado Óptico |
Centre, Departament o Servei: | Universitat Autònoma de Barcelona. Departamento de Física | Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Departamento de Física | Universidad Nacional de Colombia. Departamento de Física | Universidad de Alicante. Departamento de Física, Ingeniería de Sistemas y Teoría de la Señal | Universidad Miguel Hernández de Elche. Departamento de Ciencia de Materiales, Óptica y Tecnología Electrónica, |
Paraules clau: | Calibration | Liquid crystals | Optical metrology | Phase shifting interferometry | Surface measurement |
Àrees de coneixement: | Óptica | Física Aplicada |
Data de publicació: | de juliol-2018 |
Editor: | Elsevier |
Citació bibliogràfica: | Optics and Lasers in Engineering. 2018, 106: 147–154. doi:10.1016/j.optlaseng.2018.02.019 |
Resum: | An experimental method to calibrate Liquid Crystal on Silicon (LCoS) displays by self-generating lens configurations on the studied device is proposed in this paper. On the one hand, a split-lens is displayed in the LCoS to self-generate an interference pattern from which the phase-voltage curve of the modulator is calculated. On the other hand, a microlens array is displayed on the LCoS, within a same experimental set-up, to implement a Shack-Hartmann (S-H) wavefront sensor, from which the display surface profile is retrieved. Specifically, by means of a feasible set-up, the proposed method allows measuring the deviation from flatness of the LCoS displays as well as to determine the phase-voltage response of phase-only SLMs. Experimental results demonstrate a linear tendency phase-voltage curve that ranges from 0 rad up to ∼6.28 rad, for the used light wavelength. Moreover, by extracting the LCoS phase distribution measured with the S-H configuration, the LCoS surface inhomogeneity is corrected by 95%. |
Patrocinadors: | H. Zhang acknowledges the financial support of the Chinese Scholarship Council (CSC) (No. 201504910783). H. Zhang, A. Lizana and J. Campos acknowledge the financial support of Spanish MINECO (FIS2015-66328-C3-1-R and fondos FEDER); Catalan Government (SGR 2014-1639). C. Iemmi acknowledges the financial support of UBACyT20020130100727BA, CONICET PIP 11220150100475CO, and ANPCYT PICT 2014/2432. |
URI: | http://hdl.handle.net/10045/76367 |
ISSN: | 0143-8166 (Print) | 1873-0302 (Online) |
DOI: | 10.1016/j.optlaseng.2018.02.019 |
Idioma: | eng |
Tipus: | info:eu-repo/semantics/article |
Drets: | © 2018 Elsevier Ltd. |
Revisió científica: | si |
Versió de l'editor: | https://doi.org/10.1016/j.optlaseng.2018.02.019 |
Apareix a la col·lecció: | INV - GHPO - Artículos de Revistas |
Arxius per aquest ítem:
Arxiu | Descripció | Tamany | Format | |
---|---|---|---|---|
2018_Zhang_etal_OptLasEng_final.pdf | Versión final (acceso restringido) | 1,81 MB | Adobe PDF | Obrir Sol·licitar una còpia |
Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.