In Vitro Aberrometric Assessment of a Multifocal Intraocular Lens and Two Extended Depth of Focus IOLs

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/71578
Información del item - Informació de l'item - Item information
Título: In Vitro Aberrometric Assessment of a Multifocal Intraocular Lens and Two Extended Depth of Focus IOLs
Autor/es: Camps, Vicente J. | Tolosa, Ángel | Piñero, David P. | Fez Saiz, Dolores de | Caballero, María T. | Miret, Juan Jose
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV) | Óptica y Ciencias de la Visión
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: In vitro aberrometric | Refractive IOL | Focus IOLs | Intraocular lens
Área/s de conocimiento: Óptica
Fecha de publicación: 29-nov-2017
Editor: Hindawi Publishing Corporation
Cita bibliográfica: Journal of Ophthalmology. Volume 2017 (2017), Article ID 7095734, 7 pages. doi:10.1155/2017/7095734
Resumen: Purpose. To analyze the “in vitro” aberrometric pattern of a refractive IOL and two extended depth of focus IOLs. Methods. A special optical bench with a Shack-Hartmann wavefront sensor (SH) was designed for the measurement. Three presbyopia correction IOLs were analyzed: Mini WELL (MW), TECNIS Symfony ZXR00 (SYM), and Lentis Mplus X LS-313 MF30 (MP). Three different pupil sizes were used for the comparison: 3, 4, and 4.7 mm. Results. MW generated negative primary and positive secondary spherical aberrations (SA) for the apertures of 3 mm (−0.13 and +0.12 μm), 4 mm (−0.12 and +0.08 μm), and 4.7 mm (−0.11 and +0.08 μm), while the SYM only generated negative primary SA for 4 and 4.7 mm apertures (−0.12 μm and −0.20 μm, resp.). The MP induced coma and trefoil for all pupils and showed significant HOAs for apertures of 4 and 4.7 mm. Conclusions. In an optical bench, the MW induces negative primary and positive secondary SA for all pupils. The SYM aberrations seem to be pupil dependent; it does not produce negative primary SA for 3 mm but increases for higher pupils. Meanwhile, the HOAs for the MW and SYM were not significant. The MP showed in all cases the highest HOAs.
Patrocinador/es: This study has been partially funded by SIFI Medtech.
URI: http://hdl.handle.net/10045/71578
ISSN: 2090-004X (Print) | 2090-0058 (Online)
DOI: 10.1155/2017/7095734
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2017 Vicente J. Camps et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Revisión científica: si
Versión del editor: http://dx.doi.org/10.1155/2017/7095734
Aparece en las colecciones:INV - GOPV - Artículos de Revistas
INV - IMAOS+V - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2017_Camps_etal_JOphthalmology.pdf1,77 MBAdobe PDFAbrir Vista previa


Este ítem está licenciado bajo Licencia Creative Commons Creative Commons