Reprint of: l-Cysteine determination in embryo cell culture media using Co (II)-phthalocyanine modified disposable screen-printed electrodes

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/68569
Información del item - Informació de l'item - Item information
Títol: Reprint of: l-Cysteine determination in embryo cell culture media using Co (II)-phthalocyanine modified disposable screen-printed electrodes
Autors: Hernández Ibáñez, Naiara | Sanjuán, Ignacio | Montiel, Miguel A. | Foster, Christopher W. | Banks, Craig E. | Iniesta, Jesus
Grups d'investigació o GITE: Electroquímica Aplicada y Electrocatálisis
Centre, Departament o Servei: Universidad de Alicante. Departamento de Química Física | Universidad de Alicante. Instituto Universitario de Electroquímica
Paraules clau: Sthiol-containing compounds | l-Cysteine | Cobalt phthalocyanine | Screen-printed electrodes | Embryo cell culture media | Oxidative stress
Àrees de coneixement: Química Física
Data de publicació: 15-de maig-2017
Editor: Elsevier
Citació bibliogràfica: Journal of Electroanalytical Chemistry. 2017, 793: 77-84. doi:10.1016/j.jelechem.2017.04.034
Resum: Thiol-containing compounds such as l-cysteine have been demonstrated to play an important role in metabolism and cellular growth, acting as powerful antioxidants. Consequently, their analytical determination in biological media has received a considerable amount of attention. In this work, an electrochemical sensor for the accurate electroanalytical determination of l-cysteine is proposed, based upon a Co(II)-phthalocyanine bulk modified disposable screen-printed graphite electrode (CoPc-SPE). Cyclic (CV) and Square Wave (SWV) voltammetry experiments have demonstrated an excellent electrocatalytic activity towards the electrochemical oxidation of l-cysteine using CoPc-SPEs within optimum neutral or basic pH. Moreover, the SWV response of l-cysteine is found to exhibit a linear range of 2.6–200 μM, with a low limit of detection of 4 μM (S/N = 3) and a sensitivity of 0.78 μA cm− 2 μM− 1. Coefficient of variation for reproducibility and repeatability of l-cysteine determination using the CoPc-SPE are 3 and 0.4%, respectively. The effect of inherent interferences such as naturally occurring amino acids, cystine and cysteic acid has been also evaluated. Finally, the applicability of the l-cysteine electrochemical sensor based upon CoPc-SPEs has been successfully demonstrated for the first time for the assessment of l-cysteine in a complex embryo cell culture medium.
Patrocinadors: J. Iniesta thanks the programme Salvador de Madariaga from the Ministerio de Economía y Competitividad, grant number PRX14/00363. This work has been also financially supported by the MICINN-FEDER (Spain) through the projects CTQ2013-48280-C3-3-R.
URI: http://hdl.handle.net/10045/68569
ISSN: 1572-6657 (Print) | 1873-2569 (Online)
DOI: 10.1016/j.jelechem.2017.04.034
Idioma: eng
Tipus: info:eu-repo/semantics/article
Drets: © 2016 Published by Elsevier B.V.
Revisió científica: si
Versió de l'editor: http://dx.doi.org/10.1016/j.jelechem.2017.04.034
Apareix a la col·lecció: INV - LEQA - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
Thumbnail2017_Hernandez_etal_JElectrChem_final.pdfVersión final (acceso restringido)1,41 MBAdobe PDFObrir     Sol·licitar una còpia


Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.