Dispersive liquid–liquid microextraction for metals enrichment: A useful strategy for improving sensitivity of laser-induced breakdown spectroscopy in liquid samples analysis

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/53191
Registro completo de metadatos
Registro completo de metadatos
Campo DCValorIdioma
dc.contributorEspectroscopía Atómica-Masas y Química Analítica en Condiciones Extremases
dc.contributor.authorAguirre Pastor, Miguel Ángel-
dc.contributor.authorSelva, E.J.-
dc.contributor.authorHidalgo, Montserrat-
dc.contributor.authorCanals, Antonio-
dc.contributor.otherUniversidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatologíaes
dc.contributor.otherUniversidad de Alicante. Instituto Universitario de Materialeses
dc.date.accessioned2016-02-17T14:54:40Z-
dc.date.available2016-02-17T14:54:40Z-
dc.date.issued2015-01-
dc.identifier.citationTalanta. 2015, 131: 348-353. doi:10.1016/j.talanta.2014.07.090es
dc.identifier.issn0039-9140 (Print)-
dc.identifier.issn1873-3573 (Online)-
dc.identifier.urihttp://hdl.handle.net/10045/53191-
dc.description.abstractA rapid and efficient Dispersive Liquid–Liquid Microextraction (DLLME) followed by Laser-Induced Breakdown Spectroscopy detection (LIBS) was evaluated for simultaneous determination of Cr, Cu, Mn, Ni and Zn in water samples. Metals in the samples were extracted with tetrachloromethane as pyrrolidinedithiocarbamate (APDC) complexes, using vortex agitation to achieve dispersion of the extractant solvent. Several DLLME experimental factors affecting extraction efficiency were optimized with a multivariate approach. Under optimum DLLME conditions, DLLME-LIBS method was found to be of about 4.0–5.5 times more sensitive than LIBS, achieving limits of detection of about 3.7–5.6 times lower. To assess accuracy of the proposed DLLME-LIBS procedure, a certified reference material of estuarine water was analyzed.es
dc.description.sponsorshipThe authors are grateful to the Spanish Government (project no. CTQ2011-23968) and Regional Government of Valencia (Spain) (project no. ACOMP/2013/072) for the financial support.es
dc.languageenges
dc.publisherElsevieres
dc.rights© 2014 Elsevier B.V.es
dc.subjectDispersive liquid–liquid microextractiones
dc.subjectLIBS analysises
dc.subjectLiquid sampleses
dc.subjectTrace metals determinationes
dc.subject.otherQuímica Analíticaes
dc.titleDispersive liquid–liquid microextraction for metals enrichment: A useful strategy for improving sensitivity of laser-induced breakdown spectroscopy in liquid samples analysises
dc.typeinfo:eu-repo/semantics/articlees
dc.peerreviewedsies
dc.identifier.doi10.1016/j.talanta.2014.07.090-
dc.relation.publisherversionhttp://dx.doi.org/10.1016/j.talanta.2014.07.090es
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.relation.projectIDinfo:eu-repo/grantAgreement/MICINN//CTQ2011-23968-
Aparece en las colecciones:INV - SP-BG - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2015_Aguirre_etal_Talanta_final.pdfVersión final (acceso restringido)1,22 MBAdobe PDFAbrir    Solicitar una copia
Thumbnail2015_Aguirre_etal_Talanta_rev.pdfVersión revisada (acceso abierto)1,46 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.