Use of statistical design of experiments in the optimization of Ar–O2 low-pressure plasma treatment conditions of polydimethylsiloxane (PDMS) for increasing polarity and adhesion, and inhibiting hydrophobic recovery

Please use this identifier to cite or link to this item: http://hdl.handle.net/10045/44647
Full metadata record
Full metadata record
DC FieldValueLanguage
dc.contributorAdhesión y Adhesivoses
dc.contributor.authorButrón-García, María Isabel-
dc.contributor.authorJofre-Reche, José Antonio-
dc.contributor.authorMartín-Martínez, José Miguel-
dc.contributor.otherUniversidad de Alicante. Departamento de Química Inorgánicaes
dc.date.accessioned2015-02-09T11:47:43Z-
dc.date.available2015-02-09T11:47:43Z-
dc.date.issued2015-03-30-
dc.identifier.citationApplied Surface Science. 2015, 332: 1-11. doi:10.1016/j.apsusc.2015.01.144es
dc.identifier.issn0169-4332-
dc.identifier.urihttp://hdl.handle.net/10045/44647-
dc.description.abstractPolydimethylsiloxane (PDMS) film was treated with RF low-pressure plasmas (LPPs) made of mixtures of oxygen and argon for increasing surface polarity, minimizing hydrophobic recovery (i.e. retard ageing) and increasing adhesion to acrylic adhesive tape for medical use. Statistical design of experiments has been used for determining the most influencing experimental parameters of the LPP treatment of PDMS. Water contact angle values (measured 24 h after treatment) and the O/C ratio obtained from XPS experiments were used as response variables. Working pressure was the most influencing parameter in LPP treatment of PDMS, and the duration of the treatment, the power and the oxygen–argon mixture composition determined noticeably its effectiveness. The optimal surface properties in PDMS and inhibited hydrophobic recovery were achieved by treatment with 93 vol% oxygen + 7 vol% argon LLP at low working pressure (300 mTorr), low power (25 W) and long duration of treatment (120 s).es
dc.description.sponsorshipThis study was carried out in the framework of COST MP1101project.es
dc.languageenges
dc.publisherElsevieres
dc.rights© 2015 Elsevier B.V.es
dc.subjectPDMSes
dc.subjectLow-pressure plasmaes
dc.subjectHydrophobic recoveryes
dc.subjectWater contact anglees
dc.subjectXPSes
dc.subjectAdhesiones
dc.subject.otherQuímica Inorgánicaes
dc.titleUse of statistical design of experiments in the optimization of Ar–O2 low-pressure plasma treatment conditions of polydimethylsiloxane (PDMS) for increasing polarity and adhesion, and inhibiting hydrophobic recoveryes
dc.typeinfo:eu-repo/semantics/articlees
dc.peerreviewedsies
dc.identifier.doi10.1016/j.apsusc.2015.01.144-
dc.relation.publisherversionhttp://dx.doi.org/10.1016/j.apsusc.2015.01.144es
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
Appears in Collections:INV - LAA - Artículos de Revistas

Files in This Item:
Files in This Item:
File Description SizeFormat 
Thumbnail2015_Butron_etal_ApplSurfaceSci_final.pdfVersión final (acceso restringido)2,82 MBAdobe PDFOpen    Request a copy
Thumbnail2015_Butron_etal_ApplSurfaceSci.pdfAccepted Manuscript (acceso abierto)2,04 MBAdobe PDFOpen Preview


Items in RUA are protected by copyright, with all rights reserved, unless otherwise indicated.