Disposable electrochromic polyaniline sensor based on a redox response using a conventional camera: A first approach to handheld analysis
Empreu sempre aquest identificador per citar o enllaçar aquest ítem
http://hdl.handle.net/10045/44128
Títol: | Disposable electrochromic polyaniline sensor based on a redox response using a conventional camera: A first approach to handheld analysis |
---|---|
Autors: | Porcel-Valenzuela, María | Ballesta-Claver, Julio | Orbe-Payá, Ignacio de | Montilla, Francisco | Capitán-Vallvey, Luis Fermín |
Grups d'investigació o GITE: | Electrocatálisis y Electroquímica de Polímeros |
Centre, Departament o Servei: | Universidad de Alicante. Departamento de Química Física | Universidad de Alicante. Instituto Universitario de Materiales |
Paraules clau: | Electropolymerization | Disposable sensor | Digital camera | Electrochromism | Ascorbic acid | Hue parameter |
Àrees de coneixement: | Química Física |
Data de publicació: | 1-de febrer-2015 |
Editor: | Elsevier |
Citació bibliogràfica: | Journal of Electroanalytical Chemistry. 2015, 738: 162-169. doi:10.1016/j.jelechem.2014.12.002 |
Resum: | We present a disposable optical sensor for Ascorbic Acid (AA). It uses a polyaniline based electrochromic sensing film that undergoes a color change when exposed to solutions of ascorbic acid at pH 3.0. The color is monitored by a conventional digital camera working with the hue (H) color coordinate. The electrochromic film was deposited on an Indium Tin Oxide (ITO) electrode by cyclic voltammetry and then characterized by atomic force microscopy, electrochemical and spectroscopic techniques. An estimation of the initial rate of H, as ΔH/Δt, is used as the analytical parameter and resulted in the following logarithmic relationship: ΔH/Δt = 0.029 log[AA] + 0.14, with a limit of detection of 17 μM. The relative standard deviation when using the same membrane 5 times was 7.4% for the blank, and 2.6% (for n = 3) on exposure to ascorbic acid in 160 μM concentration. The sensor is disposable and its applicability to pharmaceutical analysis was demonstrated. This configuration can be extended for future handheld configurations. |
Patrocinadors: | We acknowledge financial support from the Junta de Andalucía (Proyecto de Excelencia P10-FQM-5974) and from the Ministerio de Economía y Competitividad (CTQ2013-44545-R). These projects were partially supported by European Regional Development Funds (ERDF). |
URI: | http://hdl.handle.net/10045/44128 |
ISSN: | 1572-6657 (Print) | 1873-2569 (Online) |
DOI: | 10.1016/j.jelechem.2014.12.002 |
Idioma: | eng |
Tipus: | info:eu-repo/semantics/article |
Revisió científica: | si |
Versió de l'editor: | http://dx.doi.org/10.1016/j.jelechem.2014.12.002 |
Apareix a la col·lecció: | INV - GEPE - Artículos de Revistas |
Arxius per aquest ítem:
Arxiu | Descripció | Tamany | Format | |
---|---|---|---|---|
2015_Porcel_etal_JEC_final.pdf | Versión final (acceso restringido) | 1,75 MB | Adobe PDF | Obrir Sol·licitar una còpia |
2015_Porcel_etal_JEC.pdf | Accepted Manuscript (acceso abierto) | 1,77 MB | Adobe PDF | Obrir Vista prèvia |
Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.