Disposable electrochromic polyaniline sensor based on a redox response using a conventional camera: A first approach to handheld analysis

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/44128
Información del item - Informació de l'item - Item information
Títol: Disposable electrochromic polyaniline sensor based on a redox response using a conventional camera: A first approach to handheld analysis
Autors: Porcel-Valenzuela, María | Ballesta-Claver, Julio | Orbe-Payá, Ignacio de | Montilla, Francisco | Capitán-Vallvey, Luis Fermín
Grups d'investigació o GITE: Electrocatálisis y Electroquímica de Polímeros
Centre, Departament o Servei: Universidad de Alicante. Departamento de Química Física | Universidad de Alicante. Instituto Universitario de Materiales
Paraules clau: Electropolymerization | Disposable sensor | Digital camera | Electrochromism | Ascorbic acid | Hue parameter
Àrees de coneixement: Química Física
Data de publicació: 1-de febrer-2015
Editor: Elsevier
Citació bibliogràfica: Journal of Electroanalytical Chemistry. 2015, 738: 162-169. doi:10.1016/j.jelechem.2014.12.002
Resum: We present a disposable optical sensor for Ascorbic Acid (AA). It uses a polyaniline based electrochromic sensing film that undergoes a color change when exposed to solutions of ascorbic acid at pH 3.0. The color is monitored by a conventional digital camera working with the hue (H) color coordinate. The electrochromic film was deposited on an Indium Tin Oxide (ITO) electrode by cyclic voltammetry and then characterized by atomic force microscopy, electrochemical and spectroscopic techniques. An estimation of the initial rate of H, as ΔH/Δt, is used as the analytical parameter and resulted in the following logarithmic relationship: ΔH/Δt = 0.029 log[AA] + 0.14, with a limit of detection of 17 μM. The relative standard deviation when using the same membrane 5 times was 7.4% for the blank, and 2.6% (for n = 3) on exposure to ascorbic acid in 160 μM concentration. The sensor is disposable and its applicability to pharmaceutical analysis was demonstrated. This configuration can be extended for future handheld configurations.
Patrocinadors: We acknowledge financial support from the Junta de Andalucía (Proyecto de Excelencia P10-FQM-5974) and from the Ministerio de Economía y Competitividad (CTQ2013-44545-R). These projects were partially supported by European Regional Development Funds (ERDF).
URI: http://hdl.handle.net/10045/44128
ISSN: 1572-6657 (Print) | 1873-2569 (Online)
DOI: 10.1016/j.jelechem.2014.12.002
Idioma: eng
Tipus: info:eu-repo/semantics/article
Revisió científica: si
Versió de l'editor: http://dx.doi.org/10.1016/j.jelechem.2014.12.002
Apareix a la col·lecció: INV - GEPE - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
Thumbnail2015_Porcel_etal_JEC_final.pdfVersión final (acceso restringido)1,75 MBAdobe PDFObrir     Sol·licitar una còpia
Thumbnail2015_Porcel_etal_JEC.pdfAccepted Manuscript (acceso abierto)1,77 MBAdobe PDFObrir Vista prèvia


Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.