New electrochemically improved tetrahedral amorphous carbon films for biological applications
Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/10045/40704
Registro completo de metadatos
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor | Electroquímica de Superficies | es |
dc.contributor.author | Laurila, Tomi | - |
dc.contributor.author | Protopopova, Vera | - |
dc.contributor.author | Rhode, Sneha | - |
dc.contributor.author | Sainio, Sami | - |
dc.contributor.author | Palomäki, Tommi | - |
dc.contributor.author | Moram, Michelle | - |
dc.contributor.author | Feliu, Juan M. | - |
dc.contributor.author | Koskinen, Jari | - |
dc.contributor.other | Universidad de Alicante. Departamento de Química Física | es |
dc.contributor.other | Universidad de Alicante. Instituto Universitario de Electroquímica | es |
dc.date.accessioned | 2014-09-29T08:52:34Z | - |
dc.date.available | 2014-09-29T08:52:34Z | - |
dc.date.issued | 2014-10 | - |
dc.identifier.citation | Diamond and Related Materials. 2014, 49: 62-71. doi:10.1016/j.diamond.2014.08.007 | es |
dc.identifier.issn | 0925-9635 (Print) | - |
dc.identifier.issn | 1879-0062 (Online) | - |
dc.identifier.uri | http://hdl.handle.net/10045/40704 | - |
dc.description.abstract | Carbon based materials have been frequently used to detect different biomolecules. For example high sp3 containing hydrogen free diamond-like carbon (DLC) possesses many properties that are beneficial for biosensor applications. Unfortunately, the sensitivities of the DLC electrodes are typically low. Here we demonstrate that by introducing topography on the DLC surface and by varying its layer thickness, it is possible to significantly increase the sensitivity of DLC thin film electrodes towards dopamine. The electrode structures are characterized in detail by atomic force microscopy (AFM) and conductive atomic force microscopy (C-AFM) as well as by transmission electron microscopy (TEM) combined with electron energy loss spectroscopy (EELS). With cyclic voltammetry (CV) measurements we demonstrate that the new improved DLC electrode has a very wide water window, but at the same time it also exhibits fast electron transfer rate at the electrode/solution interface. In addition, it is shown that the sensitivity towards dopamine is increased up to two orders of magnitude in comparison to the previously fabricated DLC films, which are used as benchmarks in this investigation. Finally, it is shown, based on the cyclic voltammetry measurements that dopamine exhibits highly complex behavior on top of these carbon electrodes. | es |
dc.description.sponsorship | The authors T.L, V.P., S.S., T.P., and J.K., would like to acknowledge the National Agency for Technology and Innovation (grant number 211488) and Aalto University (grant number 902380) for the financial support. | es |
dc.language | eng | es |
dc.publisher | Elsevier | es |
dc.subject | Tetrahedral amorphous carbon | es |
dc.subject | Thin films | es |
dc.subject | Electrochemistry | es |
dc.subject | Dopamine | es |
dc.subject | Biomaterials | es |
dc.subject.other | Química Física | es |
dc.title | New electrochemically improved tetrahedral amorphous carbon films for biological applications | es |
dc.type | info:eu-repo/semantics/article | es |
dc.peerreviewed | si | es |
dc.identifier.doi | 10.1016/j.diamond.2014.08.007 | - |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.diamond.2014.08.007 | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
Aparece en las colecciones: | INV - EQSUP - Artículos de Revistas |
Archivos en este ítem:
Archivo | Descripción | Tamaño | Formato | |
---|---|---|---|---|
2014_Laurila_etal_D&RM_final.pdf | Versión final (acceso restringido) | 1,37 MB | Adobe PDF | Abrir Solicitar una copia |
2014_Laurila_etal_D&RM.pdf | Accepted Manuscript (acceso abierto) | 1,9 MB | Adobe PDF | Abrir Vista previa |
Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.