Compensation of inorganic acid interferences in ICP-OES and ICP-MS using a Flow Blurring® multinebulizer

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/36428
Registro completo de metadatos
Registro completo de metadatos
Campo DCValorIdioma
dc.contributorEspectroscopía Atómica-Masas y Química Analítica en Condiciones Extremases
dc.contributor.authorAguirre Pastor, Miguel Ángel-
dc.contributor.authorFialhob, Lucimar L.-
dc.contributor.authorNóbrega, Joaquim A.-
dc.contributor.authorHidalgo, Montserrat-
dc.contributor.authorCanals, Antonio-
dc.contributor.otherUniversidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatologíaes
dc.contributor.otherUniversidad de Alicante. Instituto Universitario de Materialeses
dc.date.accessioned2014-04-02T11:48:19Z-
dc.date.available2014-04-02T11:48:19Z-
dc.date.issued2014-03-26-
dc.identifier.citationJournal of Analytical Atomic Spectrometry. 2014, Accepted Manuscript. doi:10.1039/C4JA00079Jes
dc.identifier.issn0267-9477 (Print)-
dc.identifier.issn1364-5544 (Online)-
dc.identifier.urihttp://hdl.handle.net/10045/36428-
dc.description.abstractA new and easy method has been proposed for compensation of inorganic acid matrix effects in ICP-OES and ICP-MS. The method consists on an on-line standard addition calibration using a Flow Blurring® multinebulizer (FBMN-based system). Experimental conditions of the FBMN-based system are optimized for both ICP-OES and ICP-MS. Under optimized conditions recovery values obtained in the analysis of synthetic acid samples were close to 100% for HNO3 and HCl (with acid concentrations of up to 15% (w w-1)) and H2SO4 (up to 10% (w w-1)) for both plasma-based spectrochemical techniques. The applicability of the proposed method has been evaluated analyzing two whole milk powders, certified reference material and a commercial product, showing excellent recovery values. Compared with other calibration strategies and experimental setups used, the on-line standard addition calibration using the FBMN-based system is faster, easier to handle and significantly reduces reagents and sample consumption.es
dc.description.sponsorshipThe authors express their gratitude to the Spanish Ministry of Science and Innovation (projects n. CTQ2008 06730-C02-01 and PHB-2010-0018-PC), to the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior in Brazil (Grant CAPES-DGU 243/11), and the Regional Government of Valencia (Spain) (projects n. ACOMP/2009/144 and ACOMP/2010/047) for financial support. The authors gratefully acknowledge OneNeb® (Division of Ingeniatrics Tecnologías S.L.) for the FBMN prototype provided. M.A.A. thanks the University of Alicante for his PhD fellowship. This work is part of the Ph.D. degree of M.A.A.es
dc.languageenges
dc.publisherRoyal Society of Chemistryes
dc.rights© Royal Society of Chemistry 2014es
dc.subjectCompensation of inorganic acid matrix effectses
dc.subjectICP-OESes
dc.subjectICP-MSes
dc.subjectFlow Blurring® multinebulizeres
dc.subject.otherQuímica Analíticaes
dc.titleCompensation of inorganic acid interferences in ICP-OES and ICP-MS using a Flow Blurring® multinebulizeres
dc.typeinfo:eu-repo/semantics/articlees
dc.peerreviewedsies
dc.identifier.doi10.1039/C4JA00079J-
dc.relation.publisherversionhttp://dx.doi.org/10.1039/C4JA00079Jes
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
Aparece en las colecciones:INV - SP-BG - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
Thumbnail2014_Aguirre_etal_JAAS.pdfAccepted Manuscript (acceso abierto)1,04 MBAdobe PDFAbrir Vista previa
Thumbnail2014_Aguirre_etal_JAAS_final.pdfVersión final (acceso restringido)295,55 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.