Determination of cyclic and linear siloxanes in wastewater samples by ultrasound-assisted dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry

Please use this identifier to cite or link to this item: http://hdl.handle.net/10045/34544
Información del item - Informació de l'item - Item information
Title: Determination of cyclic and linear siloxanes in wastewater samples by ultrasound-assisted dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry
Authors: Cortada Cortés, Carolina | Costa dos Reis, Luciana | Vidal, Lorena | Llorca, Julio | Canals, Antonio
Research Group/s: Espectroscopía Atómica-Masas y Química Analítica en Condiciones Extremas
Center, Department or Service: Universidad de Alicante. Departamento de Química Analítica, Nutrición y Bromatología
Keywords: Volatile siloxanes | Ultrasound-assisted dispersive liquid-liquid microextraction (USA-DLLME) | Experimental design | Wastewater
Knowledge Area: Nutrición y Bromatología | Química Analítica
Issue Date: 2-Dec-2013
Publisher: Elsevier
Citation: Carol Cortada, Luciana Costa dos Reis, Lorena Vidal, Julio Llorca, Antonio Canals, Determination of cyclic and linear siloxanes in wastewater samples by ultrasound-assisted dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry, Talanta, http://dx.doi.org/10.1016/j.talanta.2013.11.042
Abstract: A fast, simple and environmentally friendly ultrasound-assisted dispersive liquid-liquid microextraction (USA-DLLME) procedure has been developed to preconcentrate eight cyclic and linear siloxanes from wastewater samples prior to quantification by gas chromatography-mass spectrometry (GC-MS). A two-stage multivariate optimization approach has been developed employing a Plackett-Burman design for screening and selecting the significant factors involved in the USA-DLLME procedure, which was later optimized by means of a circumscribed central composite design. The optimum conditions were: extractant solvent volume, 13 µL; solvent type, chlorobenzene; sample volume, 13 mL; centrifugation speed, 2300 rpm; centrifugation time, 5 min; and sonication time, 2 min. Under the optimized experimental conditions the method gave levels of repeatability with coefficients of variation between 10 and 24% (n=7). Limits of detection were between 0.002 and 1.4 µg L−1. Calculated calibration curves gave high levels of linearity with correlation coefficient values between 0.991 and 0.9997. Finally, the proposed method was applied for the analysis of wastewater samples. Relative recovery values ranged between 71–116% showing that the matrix had a negligible effect upon extraction. To our knowledge, this is the first time that combines LLME and GC-MS for the analysis of methylsiloxanes in wastewater samples.
Sponsor: The authors would like to thank the Spanish Ministry of Science and Innovation (project n. CTQ2011-23968), Generalitat Valenciana (Spain) (project n. ACOMP/2013/072) and LABAQUA S.A (Alicante, Spain) for the financial support.
URI: http://hdl.handle.net/10045/34544
ISSN: 0039-9140 (Print) | 1873-3573 (Online)
DOI: 10.1016/j.talanta.2013.11.042
Language: eng
Type: info:eu-repo/semantics/article
Peer Review: si
Publisher version: http://dx.doi.org/10.1016/j.talanta.2013.11.042
Appears in Collections:INV - SP-BG - Artículos de Revistas

Files in This Item:
Files in This Item:
File Description SizeFormat 
Thumbnail2013_Cortada_etal_Talanta.pdfAccepted Manuscript (acceso abierto)602,3 kBAdobe PDFOpen Preview


Items in RUA are protected by copyright, with all rights reserved, unless otherwise indicated.