Advanced Search

RUA > Research > Óptica y Ciencias de la Visión > INV - OCIVIS - Artículos de Revistas >

Please use this identifier to cite or link to this item: http://hdl.handle.net/10045/22315

Show this item's statistics

Título: Measurement of wide frequency range structural microvibrations with a pocket digital camera and sub-pixel techniques
Autor/es: Mas Candela, David | Espinosa Tomás, Julián | Roig Hernández, Ana Belén | Ferrer Crespo, Belén | Pérez Rodríguez, Jorge | Illueca Contri, Carlos
Grupo/s de investigación o GITE: Óptica y Ciencias de la Visión | Grupo de Ensayo, Simulación y Modelización de Estructuras (GRESMES)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía | Universidad de Alicante. Departamento de Ingeniería de la Construcción, Obras Públicas e Infraestructura Urbana | Universidad de Alicante. Instituto Universitario de Física Aplicada a las Ciencias y las Tecnologías
Palabras clave: Sub-pixel techniques | Structural microvibrations
Área/s de conocimiento: Óptica | Ingeniería de la Construcción
Issue Date: 10-May-2012
Editor: Optical Society of America
Cita bibliográfica: MAS, David, et al. "Measurement of wide frequency range structural microvibrations with a pocket digital camera and sub-pixel techniques". Applied Optics. Vol. 51, No. 14 (10 May 2012). ISSN 0003-6935, pp. 2664-2671
Resumen: Analysis of vibrations and displacements is a hot topic in structural engineering. Although there is a wide variety of methods for vibration analysis, direct measurement of displacements in the mid and high frequency range is not well solved and accurate devices tend to be very expensive. Low-cost systems can be achieved by applying adequate image processing algorithms. In this paper, we propose the use of a commercial pocket digital camera, which is able to register more than 420 frames per second (fps) at low resolution, for accurate measuring of small vibrations and displacements. The method is based on tracking elliptical targets with sub-pixel accuracy. Our proposal is demonstrated at a 10 m distance with a spatial resolution of 0.15 mm. A practical application over a simple structure is given, and the main parameters of an attenuated movement of a steel column after an impulsive impact are determined with a spatial accuracy of 4 µm.
Patrocinador/es: Financial support of the Spanish Ministerio de Ciencia e Innovacion through the project FIS2009-05639-ET and BIA2011-22704, the Generalitat Valenciana through the project PROMETEO/2011/021 and the University of Alicante through the project GRE10-09. A. B. Roig thanks the support of Cajamurcia.
URI: http://hdl.handle.net/10045/22315
ISSN: 0003-6935 (Print) | 1539-4522 (Online)
DOI: 10.1364/AO.51.002664
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: This paper was published in Applied Optics and is made available as an electronic reprint with the permission of OSA. The paper can be found at the following URL on the OSA website: http://www.opticsinfobase.org/ao/abstract.cfm?URI=ao-51-14-2664. Systematic or multiple reproduction or distribution to multiple locations via electronic or other means is prohibited and is subject to penalties under law.
Revisión científica: si
Publisher version: http://dx.doi.org/10.1364/AO.51.002664
Appears in Collections:INV - OCIVIS - Artículos de Revistas
INV - GRESMES - Artículos de Revistas

Files in This Item:

File SizeFormat
Mas_et_al2012.pdf646,73 kBAdobe PDFOpen

RefWorks Export

Items in RUA are protected by copyright, with all rights reserved, unless otherwise indicated

[Web map] [Contact] [Accesibility]

© Universitat d'Alacant / Universidad de Alicante

facebook   twitter   tuenti   meneame