Higher accuracy approximate solution for oscillations of a mass attached to a stretched elastic wire by rational harmonic balance method

Empreu sempre aquest identificador per citar o enllaçar aquest ítem http://hdl.handle.net/10045/22199
Información del item - Informació de l'item - Item information
Títol: Higher accuracy approximate solution for oscillations of a mass attached to a stretched elastic wire by rational harmonic balance method
Autors: Gimeno, Encarnación | Alvarez, Mariela L. | Yebra Calleja, María Soledad | Rosa-Herranz, Julio | Beléndez, Augusto
Grups d'investigació o GITE: Holografía y Procesado Óptico | Sismología-Riesgo Sísmico y Procesado de la Señal en Fenómenos Naturales
Centre, Departament o Servei: Universidad de Alicante. Departamento de Física, Ingeniería de Sistemas y Teoría de la Señal | Universidad de Alicante. Instituto Universitario de Física Aplicada a las Ciencias y las Tecnologías
Paraules clau: Nonlinear oscillator | Analytical approximations | Rational harmonic balance method
Àrees de coneixement: Física Aplicada | Matemática Aplicada
Data de creació: de maig-2008
Data de publicació: d’abril-2009
Editor: Freund Publishing House
Citació bibliogràfica: GIMENO NIEVES, Encarnación, et al. "Higher accuracy approximate solution for oscillations of a mass attached to a stretched elastic wire by rational harmonic balance method". International Journal of Nonlinear Sciences and Numerical Simulation. Vol. 10, No. 4 (Apr. 2009). ISSN 1565-1339, pp. 493-504
Resum: A second-order modified rational harmonic balance method is used for approximately solve the nonlinear differential equation that governs the oscillations of a system typified as a mass attached to a stretched elastic wire for which the restoring force for this oscillator has an irrational term with a parameter lambda that characterizes the system. A frequency-amplitude relation is constructed and this frequency is valid for the complete range of oscillation amplitudes A and parameter lambda, and excellent agreement of the approximate frequencies with the exact one is demonstrated and discussed. The discrepancy between the approximate frequency and the exact one never exceed 0.12%. This error corresponds to lambda = 1. while for lambda < 1 the relative error is much lower. For example, its value is lower than 0.017% for lambda = 0.5.
URI: http://hdl.handle.net/10045/22199
ISSN: 1565-1339 (Print) | 2191-0294 (Online)
DOI: 10.1515/IJNSNS.2009.10.4.493
Idioma: eng
Tipus: info:eu-repo/semantics/article
Revisió científica: si
Versió de l'editor: http://dx.doi.org/10.1515/IJNSNS.2009.10.4.493
Apareix a la col·lecció: INV - GHPO - Artículos de Revistas
INV - Acústica Aplicada - Artículos de Revistas
INV - GMECA - Artículos de Revistas
INV - GIRS - Artículos de Revistas

Arxius per aquest ítem:
Arxius per aquest ítem:
Arxiu Descripció Tamany Format  
ThumbnailIJNSNS_v10_n4_p493_2009.pdf329,39 kBAdobe PDFObrir Vista prèvia


Tots els documents dipositats a RUA estan protegits per drets d'autors. Alguns drets reservats.