Análisis paramétrico mediante elementos finitos de losas de hormigón armado reforzadas frente a punzonamiento

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/104507
Información del item - Informació de l'item - Item information
Título: Análisis paramétrico mediante elementos finitos de losas de hormigón armado reforzadas frente a punzonamiento
Autor/es: Navarro Menargues, Miguel | Ivorra, Salvador | Varona Moya, Francisco de Borja
Grupo/s de investigación o GITE: Grupo de Ensayo, Simulación y Modelización de Estructuras (GRESMES)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Ingeniería Civil
Palabras clave: Finite element modelling | Numerical calibration | Punching shear | Reinforced concrete | Structural retrofitting
Área/s de conocimiento: Mecánica de Medios Continuos y Teoría de Estructuras | Ingeniería de la Construcción
Fecha de publicación: 2019
Editor: Editorial Club Universitario
Cita bibliográfica: Navarro, Miguel; Ivorra, Salvador; Varona, Francisco de Borja. “Análisis paramétrico mediante elementos finitos de losas de hormigón armado reforzadas frente a punzonamiento”. In: CMMoST 2019: 5th International Conference on Mechanical Models in Structural Engineering, Polytechnic School of Alicante, 23rd – 25th October 2019. San Vicente (Alicante): Editorial Club Universitario, 2019. ISBN 978-84-17924-58-4, pp. 63-80
Resumen: In this paper, ABAQUS is used to analyse a series of non-linear numerical models to simulate the punching shear effect on reinforced bolt-retrofitted concrete flat slabs whose bolts are arranged in three different positions around the support. To start with, an initial calibration of a finite element model was carried out with experimental results reported by Adetifa and Polak. Next, a parametric analysis was performed to determine the influence of the retrofitting geometrical parameters. For this purpose, over two hundred models were created with the help of an automation algorithm programmed in Python. Our parametric study shows that a shear-bolt radial layout may be most adequate for retrofitting slab-to-column connections in which the phenomenon of punching shear is likely to occur. Moreover, the distance between the first pair of bolts and the column’s face is recommended to be approximately five times the diameter of the shear bolts.
URI: http://hdl.handle.net/10045/104507
ISBN: 978-84-17924-58-4 | 978-84-17924-22-5
Idioma: spa
Tipo: info:eu-repo/semantics/conferenceObject
Derechos: © Los autores
Revisión científica: si
Aparece en las colecciones:CMMoST 2019 - Libro de Actas
INV - GRESMES - Comunicaciones a Congresos, Conferencias, etc.

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailCOMMoST-2019_05.pdf1,36 MBAdobe PDFAbrir Vista previa


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.