Intra and intersession reliability of the Run RocketTM in recreationally trained participants

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/101111
Registro completo de metadatos
Registro completo de metadatos
Campo DCValorIdioma
dc.contributor.authorGodwin, Mark-
dc.contributor.authorMatthews, Joseph-
dc.contributor.authorStanhope, Edward-
dc.contributor.authorRichards, Kirsty-
dc.date.accessioned2020-01-13T08:04:50Z-
dc.date.available2020-01-13T08:04:50Z-
dc.date.issued2021-
dc.identifier.citationJournal of Human Sport and Exercise. 2021, 16(1): 53-62. https://doi.org/10.14198/jhse.2021.161.05es_ES
dc.identifier.issn1988-5202-
dc.identifier.urihttps://doi.org/10.14198/jhse.2021.161.05-
dc.identifier.urihttp://hdl.handle.net/10045/101111-
dc.description.abstractSprint performance plays an important role in the success of many sports including track and field and team-based sports. Resisted sprint equipment has shown to be an effective method to increase sprint velocity and acceleration. The aim of the study was to determine the intrasession and intersession (7 days) reliability of a commercially available resisted sprint machine in recreationally trained individuals for two resistance settings. Fourteen recreationally active participants partook in the study (male = 10, female = 4) over a 7-day period. Three maximal 15m sprints, at two resistance levels (R0 and R5), were undertaken in a randomised order (6 sprints in total at each trial). Intrasession (comparison of the first 3 sprints for each trial) and intersession (mean of the 3 sprints for both trials) correlation coefficient (ICC), coefficients of variation (%CV), average variability, SEM and minimal detectable difference were calculated for 5 and 15m for both resistance levels. Intrasession reliability was very large to nearly perfect across both distances and resistance levels (ICC range 0.79-0.98), %CV ranged between 2.4-5.8% with larger values seen during the first trial for three of the four indices. Intersession reliability was very large to nearly perfect across all variables (ICC range 0.87-0.97), %CV was small and ranged between 2.0-4.1%. Average variability was small for all measurements. The Run RocketTM showed high intra and intersession reliability. The results show that this equipment could be reliably used within a sprint programme for recreationally trained individuals.es_ES
dc.languageenges_ES
dc.publisherUniversidad de Alicante. Área de Educación Física y Deportees_ES
dc.rightsLicencia Creative Commons Reconocimiento-NoComercial-SinObraDerivada 4.0es_ES
dc.subjectAthletic traininges_ES
dc.subjectSports performancees_ES
dc.subjectExercise traininges_ES
dc.subject.otherEducación Física y Deportivaes_ES
dc.titleIntra and intersession reliability of the Run RocketTM in recreationally trained participantses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.peerreviewedsies_ES
dc.identifier.doi10.14198/jhse.2021.161.05-
dc.relation.publisherversionhttps://www.jhse.ua.es/es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
Aparece en las colecciones:Journal of Human Sport and Exercise - 2021, Vol. 16, No. 1

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailJHSE_16-1_05.pdf276,25 kBAdobe PDFAbrir Vista previa


Este ítem está licenciado bajo Licencia Creative Commons Creative Commons